PartNumber | 100V/s (V) | 1000V/us (V) | 8/20μs 10times(KA) | 10/1000μs 100A (times) | 50Hz1sec (A) | Test Voltage DC (V) | (GΩ) | Capacitance (pF) | Datasheet |
---|---|---|---|---|---|---|---|---|---|
2RM120L-5 | 120±20% | 600 | 10 | 500 | 10 | 50 | 1 | 1.5 | |
2RM120M-5 | 120±20% | 600 | 10 | 500 | 10 | 50 | 1 | 1.5 | |
2RL120L-5 | 120±20% | 700 | 5 | 300 | 5 | 50 | 1 | 1.5 | |
2RM145L-5 | 145±20% | 700 | 10 | 500 | 10 | 100 | 1 | 1.5 | |
2RM145M-5 | 145±20% | 700 | 10 | 500 | 10 | 100 | 1 | 1.5 | |
2RL145L-5 | 145±20% | 700 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RL145M-5 | 145±20% | 700 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RM150L-5 | 150±20% | 700 | 10 | 500 | 10 | 100 | 1 | 1.5 | |
2RL150L-5 | 150±20% | 700 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RM230L-5 | 230±20% | 700 | 10 | 500 | 10 | 100 | 1 | 1.5 | |
2RL230L-5 | 230±20% | 700 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RL250L-5 | 250±20% | 700 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RL300L-5 | 300±20% | 900 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RL350L-5 | 350±20% | 900 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RK3600L-5 | 3600±20% | 5000 | 3 | 300 | - | 1000 | 1 | 1.5 | |
2RK3600M-5 | 3600±20% | 5000 | 3 | 300 | - | 1000 | 1 | 1.5 | |
2RL400L-5 | 400±20% | 1000 | 5 | 300 | 5 | 100 | 1 | 1.5 | |
2RL470L-5 | 470±20% | 1100 | 5 | 300 | 5 | 250 | 1 | 1.5 | |
2RL600L-5 | 600±20% | 1500 | 5 | 300 | 5 | 250 | 1 | 1.5 | |
2RM070L-5 | 70±20% | 600 | 10 | 500 | 5 | 25 | 1 | 1.5 | |
2RM070M-5 | 70±20% | 600 | 10 | 500 | 5 | 25 | 1 | 1.5 | |
2RL070L-5 | 70±20% | 800 | 5 | 300 | 5 | 25 | 1 | 1.5 | |
2RL070M-5 | 70±20% | 800 | 5 | 300 | 5 | 25 | 1 | 1.5 | |
2RM075L-5 | 75±20% | 600 | 10 | 500 | 5 | 25 | 1 | 1.5 | |
2RL075L-5 | 75±20% | 800 | 5 | 300 | 5 | 25 | 1 | 1.5 | |
2RL800L-5 | 800±20% | 1700 | 5 | 300 | 5 | 250 | 1 | 1.5 | |
2RL800M-5 | 800±20% | 1700 | 5 | 300 | 5 | 250 | 1 | 1.5 | |
2RM090L-5 | 90±20% | 600 | 10 | 500 | 10 | 50 | 1 | 1.5 | |
2RL090L-5 | 90±20% | 700 | 5 | 300 | 5 | 50 | 1 | 1.5 |
GDT is a good solution for surge protection. The insulation resistance of GDT is over 1GΩ, which achieves low degradation speed and high reliability.
GDT is a good solution for surge protection. The insulation resistance of GDT is over 1GΩ, which achieves low degradation speed and high reliability.
GDT is a good solution for surge protection. The insulation resistance of GDT is over 1GΩ, which achieves low degradation speed and high reliability.
GDT is a good solution for surge protection. The insulation resistance of GDT is over 1GΩ, which achieves low degradation speed and high reliability.